AUTOMATIC TRANSMISSION ± On-vehicle Service
23-42
OUTPUT SHAFT SPEED SENSOR CHECK
1. Disconnect the output shaft speed sensor connector.
2. Measure the resistance between terminals 3 and 4 of
the output shaft speed sensor connector.
Standard value: 430 ± 43 Ω (at 20 _C)
3. If the resistance is not within the standard value, replace
the output shaft speed sensor.
SOLENOID VALVE CHECK
1. Disconnect the solenoid valve connector.
2. Measure the solenoid valve resistance.
Standard value:
Item Measurement
terminal
Resistance
Solenoid valve No. 1 Between terminal 6
and earth
13 ± 2 Ω
(at 25_C)
Solenoid valve No. 2 Between terminal 7
and earth
Solenoid valve No. 3 Between terminal 8
and earth
3. If the resistance is not within the standard value, replace
the solenoid valve assembly.
Output shaft speed sensor
Solenoid valve No. 3
Solenoid valves