BODY ± Keyless Entry SystemBODY ± Keyless Entry System
42-41
3. Adjustment of functions
Function Adjustment procedure
Keyless entry answerback function When the transmitter lock switch is turned on twice continuously within 2
seconds, the lock answerback function toggles on and off.
D If the function toggles on, the buzzer sounds once (default condition).
D If the function toggles off, the buzzer sounds twice,
When the transmitter unlock switch is turned on twice continuously within 2
seconds, the unlock answerback function toggles on and off.
D If the function toggles on, the buzzer sounds once (default condition).
D If the function toggles off, the buzzer sounds twice,
Initialization of all the ETACS func-
tions (From desactivation to activa-
tion)
When the windshield washer switch remains on for more than 20 seconds, the
buzzer sounds twice and then all of the following functions will be initialized.
D Automatic lighting sensor sensitivity
D Automatic headlamp switch-off function
D Vehicle-speed dependent wiper
D Outside mirror automatic rest function
The buzzer will sound in 10 seconds (indicating that the ETACS-ECU enters
the adjustment mode), but the washer switch must remains off for 20 seconds
in order to initialize all the functions.
If the windshield washer switch remains on for more than 20 seconds without
entering the adjustment mode, the system enters the adjustment mode in 10
seconds, but does not initialize all of the functions.
KEYLESS ENTRY SYSTEM
REMOVAL AND INSTALLATION
Pre-removal and Post-installation Operation
Side Cover Removal and Installation
(See GROUP 52A ± Instrument Panel.)
ETACS-ECU