The Computer
5-50 Manual # 42-02-1P21
CANCEL BOTH HALL (U/D) CALLS YES/NO - If set to NO, when servicing a hall
call, only the call in the direction of travel is canceled. If set to YES, when servicing a hall call,
calls in both up and down directions are canceled.
RETAIN CALLS ON CTL/CTF? YES/NO - If set to No, when a Car-to-Lobby or Car-to-
Floor function is activated, latched car calls are serviced and then the car moves to the return or
lobby floor. If set to Yes, when CTL or CTF is activated, the car moves to the return or lobby
floor immediately, but any un-serviced car calls remain latched. When CTL/CTF is dropped, the
retained calls are serviced.
AUTOMATIC FLOOR STOP OPTION? / AUTOMATIC STOP FLOOR #?
When this option is set to a specific floor number, the car will automatically stop at that floor if
its travel would cause it to pass that floor.
CC CANCEL W/DIR REVERSAL? This option will cause all of the previously regis-
tered car calls to be canceled whenever a direction reversal is detected.
CANCEL CAR CALLS BEHIND CAR? If this option is set to YES and the car has a
direction arrow (SUA/SDA), no car calls can be registered behind the car's current position. For
example: If a car is at the fifth floor moving down, no car calls can be registered from sixth floor
and above.
CE ELECTRONICS BOARD? REV 1/REV 2 - This option allows information such as
position and arrival gong outputs to be provided for a CE electronics device. This option is to be
used with the CE Electronics Interface board (Rev 1 and Rev 2) which provides a 3-wire serial
interface to CE electronic fixtures.
MASSACHUSETTS EMS SERVICE? / EMS SERVICE FLOOR # This option is
provided in the state of Massachusetts only. This option is key-operated and provides immedi-
ate car service for Massachusetts Emergency Medical Service personnel.
BSI SECURITY KEY This option is a board-level control of the security system. Stan-
dard Security is initiated by the BSI Security Key. There are three possible settings for the BSI
Security Key: ACTIVATED, ENABLED or DEACTIVATED.
If set to ACTIVATED, Security is initiated.
If set to ENABLED, Security is initiated only if the Building Security Input (BSI) is turned
On.
If set to DEACTIVATED, Security is deactivated regardless of the status of the BSI input.
PI TURNED OFF IF NO DEMAND? Setting this option to YES will allow the PI out-
puts to turn OFF if the car has been inactive for an adjustable time (from 1 to 10 minutes) as
determined by the fan/light timer. Please refer to “FAN/LIGHT OUTPUT TIMER” on page 5-
27.
HOSPITAL EMERG. OPERATION? This option calls any eligible in-service elevator
to any floor on an emergency basis. If this installation has Hospital Emergency Service Opera-
tion, a hospital emergency call switch will be installed at each floor where this service is desired.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motion Control Engineering 2000 and is the answer not in the manual?

Motion Control Engineering 2000 Specifications

General IconGeneral
BrandMotion Control Engineering
Model2000
CategoryController
LanguageEnglish

Related product manuals