Troubleshooting
6-42 Manual # 42-02-1P21
J10
MCE wired
at factory.
Not for field
connection.
ICTD See description, connector J27
ICTU See description, connector J27
CTEN See description, connector J27
INCT See description, connector J27
FRS See description, connector J27
FRA See description, connector J27
J11
MCE wired
at factory.
Not for field
connection.
ABD See description, connector J27
ABU See description, connector J27
ATD See description, connector J27
ATU See description, connector J27
INA See description, connector J27
INN See description, connector J27
INCP See description, connector J27
ICEN See description, connector J27
J12 GSR Gate switch rear (rear opening car gate switch “made” input)
DCABR Door contact access bottom rear (bottom access floor rear door contact “made”
input)
DLABR Door lock access bottom rear (bottom access floor rear door lock “made” input)
DLMS Door lock middle string (floors between access floors, contacts “made” input)
DLAT Door lock access top (top access floor door lock “made” input)
DZF Front door zone input, discrete landing system connection
DZR Rear door zone input, discrete landing system connection
LIM0 Used with hydro applications only
LIM1 Used with hydro applications only
LIM2 Used with hydro applications only
LIM3 Used with hydro applications only
GS Gate switch (car gate switch “made” input)
DCAB Door contact access bottom (bottom access floor door contact “made” input)
DLAB Door lock access bottom (bottom access floor door lock “made” input)
DCMS Door contact middle string (floors between access floors, contacts “made” input)
DCAT Door contact access top (top access floor door contact “made” input)
SAFH Safety string, hoistway (input)
SAFC Safety string, car (input)
ESC In-car stop switch bypass (completes SAFC safety string with switch open)
SPD0 Speed bit from LS-EDGE landing system sensor
SPD1 Speed bit from LS-EDGE landing system sensor
SPD2 Speed bit from LS-EDGE landing system sensor
J14 SPOUT1 Programmable spare output #1. Defined on job prints if used.
SPOUT2 Programmable spare output #2. Defined on job prints if used.
SPOUT3 Programmable spare output #3. Defined on job prints if used.
SPOUT4 Programmable spare output #4. Defined on job prints if used.
Table 6.3 HC-CTL-2 Board Terminals
Connector Terminal Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motion Control Engineering 2000 and is the answer not in the manual?

Motion Control Engineering 2000 Specifications

General IconGeneral
BrandMotion Control Engineering
Model2000
CategoryController
LanguageEnglish

Related product manuals