Diagnostic Mode
5-11
5
DOL Door open limit input 20 5 SCE Stepping correction enable 25 8
DOLM Door open limit memory flag 20 8 SD Supervisory down flag 2E 8
DOLMR Door open limit memory flag (rear) 10 8 SDA Down direction arrow 2E 7
DOLR Door open limit (rear) 10 5 SDT Short door time flag 22 1
DPD Down previous direction 29 6 SDTR Short door time flag (rear) 12 1
DPR Door protection timer flag 26 3 SE Safety edge input 23 7
DSD Down slow down input 2E 6 SER Safety edge input (rear) 13 7
DSH Door shortening flag 2B 2 SLV Stable slave flag 38 7
DSHT Door shortening flag 23 1 SST Soft stop timer flag 2B 5
DSHTR Door shortening flag (rear) 13 1 STC Stepping complete flag 2C 7
DZ Door zone input 20 6 STD/R0
Step down input/absolute floor
encoding #0
24 2
DZORDZ Front or rear door zone input 2D 6 STU/R1
Step up input/absolute floor
encoding #1
24 1
DZP Door zone previous 2C 8 SU Supervisory up flag 2E 4
DZR Door zone input (rear) 10 6 SUA Up direction arrow 2E 3
ECC Excess car calls flag 2F 5 TEMPB Temporary bit 2D 8
ECRN Emergency car run flag 2F 3 TEST Test switch input 33 6
EPI Emergency power input flag 31 1 TFA Timing function active 21 8
EPR Emergency power return 2F 2 TFAR Timing function active (rear) 11 8
EPRUN Emergency power run input 31 2 TFD Top floor demand flag 2E 1
EPSTP Emergency power stop input 31 4 TOS Timed out of service flag 2B 8
EXMLT External Motor Limit Timer 25 3 UC Up call flag 21 6
FCCC Fire phase II car call cancel 25 7 UCA Up call above flag 2A 2
FCHLD Fire phase II hold 25 6 UCB Up call below flag 2A 6
FCOFF Fire phase II off 27 7 UCR Up call flag (rear) 11 6
FCS Fire phase II input 24 6 UDP Up direction preference 29 1
FCSM Fire service phase II input memory 2D 5 UFP Upper parking floor flag 26 7
FDC Door fully closed phase II 21 3 UFQ Up first qualifier flag 2D 7
FDCR Door fully closed phase II (rear) 11 3 UPD Up previous direction 29 2
FRA Alt. Fire service phase I input 24 7 UPDO Up direction output 29 4
FRAS Alternate fire flag 2D 2 UPS Up direction sense input 24 3
FRBYP Fire phase I bypass input flag 2F 8 USD Up slow down input 2E 2
FRC Fire phase II flag 2D 1 VCA Viscosity active 25 4
FREE No demand and in service 30 5 VCI Viscosity Input 24 8
FRM Fire service phase I flag 2D 4 VLT Valve limit timer 2B 6
FRON Fire phase I on input flag 2F 7
Table 5.4 Alphabetized Flags/Variables and Their Locations
FLAG Definition Add
Position
FLAG Definition Add
Position

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motion Control Engineering 2000 and is the answer not in the manual?

Motion Control Engineering 2000 Specifications

General IconGeneral
BrandMotion Control Engineering
Model2000
CategoryController
LanguageEnglish

Related product manuals