EasyManua.ls Logo

Motorola MPC823e - Page 592

Motorola MPC823e
1353 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Communication Processor Module
16-138 MPC823e REFERENCE MANUAL MOTOROLA
SERIAL
I/F
COMMUNICATION
16
PROCESSOR MODULE
R2CS—Receive Clock Source for SCC2
This field is ignored when the SCC2 is connected to the time-slot assigner (SC2 = 1).
000 = SCC2 receive clock is BRG1.
001 = SCC2 receive clock is BRG2.
010 = SCC2 receive clock is BRG3.
011 = SCC2 receive clock is BRG4.
100 = SCC2 receive clock is CLK1.
101 = SCC2 receive clock is CLK2 .
110 = SCC2 receive clock is CLK3 .
111 = SCC2 receive clock is CLK4 .
T2CS—Transmit Clock Source for SCC3
This field is ignored when SCC3 is connected to the time-slot assigner (SC3 = 1).
000 = SCC3 transmit clock is BRG1.
001 = SCC3 transmit clock is BRG2.
010 = SCC3 transmit clock is BRG3.
011 = SCC3 transmit clock is BRG4.
100 = SCC3 transmit clock is CLK1.
101 = SCC3 transmit clock is CLK2.
110 = SCC3 transmit clock is CLK3.
111 = SCC3 transmit clock is CLK4.
Bits 24–25—Reserved
These bits are reserved and must be set to 0.
R1CS—Clock Source for the USB
000 = USB clock is BRG1.
001 = USB clock is BRG2.
010 = USB clock is BRG3.
011 = USB clock is BRG4.
100 = USB clock is CLK1.
101 = USB clock is CLK2.
110 = USB clock is CLK3.
111 = USB clock is CLK4.
Bits 29–31—Reserved
These bits are reserved and must be set to 0.