Configure System Information
105
M4100 Series Managed Switch
Media Application Type The application type. Types of applications are unknown,
voicesignaling, guestvoice, guestvoicesignalling,
softphonevoice, videoconferencing, streammingvideo,
and vidoesignalling. Each application type that is
received has the VLAN ID, priority, DSCP, tagged bit
status, and unknown bit status. A port can receive one or
many such application types. Only when a network policy
TLV was received on this port, is this information
displayed.
VLAN Id The VLAN ID associated with a particular policy type.
Priority The priority associated with a particular policy type.
DSCP The DSCP associated with a particular policy type.
Unknown Bit Status The unknown bit associated with a particular policy type.
Tagged Bit Status The tagged bit associated with a particular policy type.
Inventory Information: Specifies if the inventory TLV is received in LLDP frames on this port.
Hardware Revision The hardware version of the remote device.
Firmware Revision The Firmware version of the remote device.
Software Revision The Software version of the remote device.
Serial Number The serial number of the remote device.
Manufacturer Name The manufacturers name of the remote device.
Model Name The model name of the remote device.
Asset ID The asset ID of the remote device.
Location Information: Specifies if the location TLV is received in LLDP frames on this port.
Sub Type The type of location information.
Location Information The location information as a string for given type of
location ID.
Extended POE: Specifies if the remote device is a PoE device.
Device Type The remote device's PoE device type connected to this
port.
Extended POE PSE: Specifies if the extended PSE TLV is received in LLDP frame on this port.
Available The remote port’s PSE power value in tenths of watts.
Source The remote port’s PSE power source.
Priority The remote port’s PSE power priority.
Extended POE PD: Specifies if the extended PD TLV is received in LLDP frame on this port.
Table 30. LLDP-MED remote device information (continued)
Field Description

Table of Contents

Other manuals for NETGEAR M4100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4100 Series and is the answer not in the manual?

NETGEAR M4100 Series Specifications

General IconGeneral
BrandNETGEAR
ModelM4100 Series
CategorySwitch
LanguageEnglish

Related product manuals