Variable name EIP_Comm2Status.IdentityErr
Meaning CIP Communications2 Identity Error Global/local Global
Function Indicates that the identity information for CIP communications 2 (which you cannot overwrite) is incorrect. Or, a
read operation failed.
TRUE: Setting incorrect or read failed.
F
ALSE: Normal
Data type BOOL Range of values TRUE or F
ALSE
R/W access R Retained Not retained. Network Publish Do not publish.
Usage in user pro-
gram
Possible. Related in-
structions
---
Variable name EIP_Comm1Status.TDLinkCfgErr
Meaning CIP Communications1 Tag Data Link Setting
Error
Global/local Global
Function Indicates that the tag data link settings for CIP communications 1 are incorrect. Or, a read operation failed.
TRUE: Setting incorrect or read failed.
F
ALSE: Normal
Data type BOOL Range of values TRUE or F
ALSE
R/W access R Retained Not retained. Network Publish Do not publish.
Usage in user pro-
gram
Possible. Related in-
structions
---
Variable name EIP_Comm2Status.TDLinkCfgErr
Meaning CIP Communications2 Tag Data Link Setting
Error
Global/local Global
Function Indicates that the tag data link setting for CIP communications 2 are incorrect. Or, a read operation failed.
TRUE: Setting incorrect or read failed.
F
ALSE: Normal
Data type BOOL Range of values TRUE or F
ALSE
R/W access R Retained Not retained. Network Publish Do not publish.
Usage in user pro-
gram
Possible. Related in-
structions
---
Variable name EIP_Comm1Status.TDLinkOpnErr
Meaning CIP Communications1 Tag Data Link Connec-
tion Failed
Global/local Global
Function Indicates that establishing a tag data link connection for CIP communications 1 failed.
TRUE: Establishing a tag data link connection failed due to one of the following causes.
The information registered for a target node in the tag data link parameters is different from the actual node
information.
There was no response from the remote node.
F
ALSE: Other than the above.
Data type BOOL Range of values TRUE or FALSE
R/W access R Retained Not retained. Network Publish Do not publish.
Usage in user pro-
gram
Possible. Related in-
structions
---
6 Device Variables Related to the NX-series EtherNet/IP Unit