500
DP-C405/C305/C265
FEB 2008Ver. 1.1
F4 Mode (Output Check)
No. Item Function Remark
200 Lamp When SCN PCB CN704-1, CN704-4 signal
level changes to 0V from +24V, Lamp
operates for 4 seconds.
201 ADF Motor 1 Rotating
(50% rotation speed)
ADF Motor 1 spins at a 50% rate.
202 ADF Motor 1 Rotating
(100% rotation speed)
ADF Motor 1 spins at a 100% rate.
203 ADF Motor 1 Rotating
(400% rotation speed)
ADF Motor 1 spins at a 400% rate.
204 ADF Motor 2 Reverse Rotating
(50% rotation speed)
ADF Motor 2 spins in reverse at a 50% rate.
205 ADF Motor 2 Reverse Rotating
(100% rotation speed)
ADF Motor 2 spins in reverse at a 100% rate.
206 ADF Motor 2 Reverse Rotating
(400% rotation speed)
ADF Motor 2 spins in reverse at a 400% rate.
207 ADF Paper Feed Roller Clutch When CN655-2 signal level changes to 0V
from +24V, clutch operates for 3 seconds.
208 ADF Registration Roller 1 Clutch When CN656-4 signal level changes to 0V
from +24V, clutch operates for 3 seconds.
209 ADF Registration Roller 2 Clutch When CN656-2 signal level changes to 0V
from +24V, clutch operates for 3 seconds.
210 ADF Inverting Roller 1 Clutch When CN659-6 signal level changes to 0V
from +24V, clutch operates for 3 seconds.
211 ADF Inverting Roller 2 Clutch When CN659-7 signal level changes to 0V
from +24V, clutch operates for 3 seconds.
212 ADF Speed Down Clutch When CN659-5 signal level changes to 0V
from +24V, clutch operates for 3 seconds.
213 ADF Solenoid When CN660-7 signal level changes to 0V
from +24V, Solenoid operates for 200ms.
214 ADF Inverting Solenoid When CN660-5 signal level changes to 0V
from +24V, Solenoid operates for 200ms.
215 ADF Pinch Roller Solenoid When CN660-2 signal level changes to 0V
from +24V, Solenoid operates for 1 second.
216 ADF Stamp Solenoid When CN658-2 signal level changes to 0V
from +24V, Solenoid operates for 1 second.
217-
299
Not Used
F4 Mode (Input Check)
No. Function Condition
Message Display
Remarks
76543210
300 100V/200V LVPS Signal
(DP-C354 / C322 Series Only)
LVPS is connected. 0 1 : 200V LVPS
24V F PS "On" Detection
(DP-C354 / C322 Series Only)
+24V PS Voltage is Off. 1
24V M PS “On” Detection +24V PS Voltage is Off. 1

Table of Contents