DP-C405/C305/C265
FEB 2008Ver. 1.1
7 Installation (For PU)
7.1. Precautions During Set Up
Before you begin the installation, read these entire instructions. You must locate an appropriate site (firm
and leveled surface) for the installation. Reading this section assists you with the decision making process.
Machine performance and copy quality is subject to, and dependant on environmental conditions.
To maintain good performance, quality, and safe operation, observe the following precautions:
1. For safe operation and to avoid trouble, do not install the system under the following conditions:
• High temperature, high humidity, low temperature or low humidity.
Ambient conditions Temperature : 50 - 86 °F (10 - 30 °C)
Relative humidity : 30 - 80 %
• Sudden changes in temperature or humidity
• Exposed to direct sunlight
• Dusty environment
• Poorly ventilated location
• Exposed to chemical gases (such as ammonia gas)
• Exposed to strong vibration
• Exposed to direct air current (ex: Air conditioner vent)
2. The weight of the machine (Scanner mounted; options not included) is as follows:
DP-C405 / C305 / C265 : Approx. 360.8 lb (164 kg)
Options:
DA-DS320 / DS321 (Paper Tray) : Approx. 58.3 lb (26.5 kg) / 60.4 lb (27.4 kg)
DA-FS402 (1 Bin Finisher) : Approx. 23.4 lb (10.6 kg)
DA-FS405 (1 Bin Saddle-Stitch Finisher) : Approx. 81.4 lb (37 kg)
Place the machine on a level, and sturdy surface that can withstand the weight of the machine. If tilted,
the machine may tip-over, causing injuries.
3. The maximum power consumption is less than 1.5 kW. Depending on the product destination, the wall
outlet must be rated for 120 VAC or 220-240 VAC accordingly. It must also be protected for at least 15
amps for 120 VAC, or 10 amps for 220-240 VAC. If you are in doubt about a power source, ensure that
a qualified electrician checks the outlet. Do not connect any other devices to the wall outlet designated
for this machine. (Do not use an extension cord)
4. Make sure the outlet is properly grounded. (Do not ground to a gas or water pipe)
5. The machine should be installed in a well-ventilated area to minimize the ozone density in the air.
6. This machine has ventilation openings on the side and rear, which must remain unobstructed for safe
operation. The machine should be located at least 3.94 inches (100 mm) from the wall. Obstructing the
ventilation openings could present a fire hazard.
Using the space requirements shown on the following page, ensures that the machine has the
ventilation it requires, and that you have the space needed for replacing the supplies.
7. There is a remote possibility of electrocution when installing the Fax option during a Lightning Storm.
As a precaution, plug the AC Power Cord first, before connecting the Telephone Line Cable.