5.2.5.4. Binary Signal (V.34)
This Service Mode is used to check the binary signal output. Signals can be output to the line using the
following procedure. (V.34)
Set the machine to Service Mode, and press the “9” key on the Control Panel.
Press the “Start” key to enter the F9 Service Mode on the Control Panel.
Select “00 Fax Service Mode” on the Touch Panel display.
Select “04 Modem tests” on the Touch Panel display.
Scroll the menu with the “” button on the Touch Panel display, and select “05 V34 Modem”.
Select the desired parameter on the Touch Panel display, and then press the “Start” key on the Control
Panel.
Press the “Stop” key on the Control Panel.
Select the “Close” button three time on the Touch Panel display.
Press the “Function”, and the “C (Clear)” keys simultaneously on the Control Panel to exit the Service
Mode.
Binary Signal Table
Signals Signals Signals
V34 2400 sr 2400 bps V34 3000 sr 9600 bps V34 3429 sr 4800 bps
V34 2400 sr 4800 bps V34 3000 sr 12000 bps V34 3429 sr 7200 bps
V34 2400 sr 7200 bps V34 3000 sr 14400 bps V34 3429 sr 9600 bps
V34 2400 sr 9600 bps V34 3000 sr 16800 bps V34 3429 sr 12000 bps
V34 2400 sr 12000 bps V34 3000 sr 19200 bps V34 3000 sr 19200 bps
V34 2400 sr 14400 bps V34 3000 sr 21600 bps V34 3429 sr 16800 bps
V34 2400 sr 16800 bps V34 3000 sr 24000 bps V34 3429 sr 19200 bps
V34 2400 sr 19200 bps V34 3000 sr 26400 bps V34 3429 sr 21600 bps
V34 2400 sr 21600 bps V34 3000 sr 28800 bps V34 3429 sr 24000 bps
V34 2800 sr 4800 bps V34 3200 sr 4800 bps V34 3429 sr 26400 bps
V34 2800 sr 7200 bps V34 3200 sr 7200 bps V34 3429 sr 28800 bps
V34 2800 sr 9600 bps V34 3200 sr 9600 bps V34 3429 sr 31200 bps
V34 2800 sr 12000 bps V34 3200 sr 12000 bps V34 3429 sr 33600 bps
V34 2800 sr 14400 bps V34 3200 sr 14400 bps ANSam
V34 2800 sr 16800 bps V34 3200 sr 16800 bps CM
V34 2800 sr 19200 bps V34 3200 sr 19200 bps JM
V34 2800 sr 21600 bps V34 3200 sr 21600 bps INFO0c & TONEB
V34 2800 sr 24000 bps V34 3200 sr 24000 bps INFO0c & TONEA
V34 2800 sr 26400 bps V34 3200 sr 26400 bps PPh & AC & ALT
V34 3000 sr 4800 bps V34 3200 sr 28800 bps
V34 3000 sr 7200 bps V34 3200 sr 31200 bps