548
DP-C405/C305/C265
FEB 2008Ver. 1.1
841 Color Reg Calib. C Middle sensor color registration LED intensity
target value adjustment.
-127 ~ +127
0.016 mV
842 Color Reg Calib. R Right sensor color registration LED intensity
target value adjustment.
-127 ~ +127
0.016 mV
843-
844
Not Used
845 Color Reg Sensor mon. L Left sensor color registration LED intensity target
value monitor adjustment.
0 ~ +255
(Read Only)
846 Color Reg Sensor mon. C Middle sensor color registration LED intensity
target value monitor adjustment.
0 ~ +255
(Read Only)
847 Color Reg Sensor mon. R Right sensor color registration LED intensity
target value monitor adjustment.
0 ~ +255
(Read Only)
848-
849
Not Used
850 Color Reg Slice L Color registration of left sensor slice level
adjustment.
-127 ~ +127
0.016 mV
851 Color Reg Slice C Color registration of middle sensor slice level
adjustment.
-127 ~ +127
0.016 mV
852 Color Reg Slice R Color registration of right sensor slice level
adjustment.
-127 ~ +127
0.016 mV
853-
854
Not Used
855 Skew Y Right rotation Color (Y) skew registration adjustment. -99 ~ +99
(Read Only)
856 Skew M Right rotation Color (M) skew registration adjustment. -99 ~ +99
(Read Only)
857 Skew C Right rotation Color (C) skew registration adjustment. -99 ~ +99
(Read Only)
858 Color Reg Main Max Maximum dot color horizontal registration
adjustment.
-127 ~ +127
(Read Only)
859 Color Reg Sub Max Maximum dot color vertical registration
adjustment.
-127 ~ +127
(Read Only)
860 Color Reg Offset L-Y Color registration horizontal offset for left sensor
adjustment.
-3 ~ +3
1 dot
861 Color Reg Offset C-Y Color registration horizontal offset for middle
sensor adjustment.
-3 ~ +3
1 dot
862 Color Reg Offset R-Y Color registration horizontal offset right sensor
adjustment.
-3 ~ +3
1 dot
863-
998
Not Used
999 F5/F6 Initialization Resets the Parameters to default values.
F6 Mode
No. Item Remarks Setting Range

Table of Contents