6-24 Safe Torque Off
AC30 series Variable Speed Inverter
SS1 IMPLEMENTATION USING SAFETY CONTROL UNIT
This Safe Stop 1 (SS1) implementation causes the drive to come to rest in a controlled manner, and STO is actioned after a time delay determined by
the safety delay relay. This conforms to SS1 defined in EN61800-5-2:2007 para 4.2.2.3 c). The example shows wiring and terminal numbering for a
Siemens 3TK2827, but similar products are available from other vendors. Use of this Siemens part does not imply it is suitable for the user’s application.
The user must select and assess appropriate equipment.
Note: On power-up, the Safety Control Unit outputs are OPEN; thus STO is requested of the inverter. This responds by energising KA1 if both channels
are active and healthy. KA1 is used as a self-check for the reset cycle of the Safety Control Unit. If a reset cannot be achieved due to KA1 being de-
energised, a fault may be present and must be resolved by the user before relying on the STO function. See Fault Operation on page 6-14.
A2
PE
Y33
24VDC
SAFETY
DEMAND
KA1
POWER
SUPPLY
SAFETY CONTROL UNIT
THIS WIRING MUST BE WITHIN THE CONTROL CUBICLE.
KA1
INVERTER STO
RESE
T
DRIVE
START
DRIVE STOP
X13/02
X12/01
X10/01
X10/03
X10/06
X12/05
X10/02
X10/04
X10/05
X12/06
A1
Y10
Y11
Y12
Y21
Y22
13
47
57
Y34
14
48
58