Parameter Reference D-163
AC30 series Variable Speed Drive
Spd Loop Diagnostics
Parameters::Motor Control::Spd Loop Diagnostics
Refer to the diagram in Spd Loop Settings function.
Only applies to SVC control mode, IM or PMAC.
Parameter Name
No.
Path
Default
Range
Units
Writable
Total Spd Demand RPM
0533
Parameters::Motor Control::Spd Loop
Diagnostics
x.xx
-100000.00 to 100000.00
RPM
NEVER
This diagnostic shows the final values of the speed demand in rpm obtained after summing all sources. This is the value which is
presented to the speed loop
Total Spd Demand %
0534
Parameters::Motor Control::Spd Loop
Diagnostics
x.xx
-200.00 to 200.00
%
NEVER
This diagnostic shows the final values of the speed demand as a % of 100% Speed in RPM of the Scale Setpoint obtained after
summing all sources. This is the value which is presented to the speed loop.
Speed Loop Error
0535
Parameters::Motor Control::Spd Loop
Diagnostics
x.xx
-400.00 to 400.00
%
NEVER
This diagnostic shows the difference between the total speed demand and the speed feedback
Speed PI Output
0536
Parameters::Motor Control::Spd Loop
Diagnostics
x.xx
-500.00 to 500.00
%
NEVER
This diagnostic shows the torque demand due to the speed loop PI output, not including any feedforward terms.