Loading...
Parameter Reference D-41
AC30 series Variable Speed Drive
Current Loop
Setup:: Motor Control::Control & Type:: Motor Type
Parameters::Motor Control::Control Loop
Parameter Name
No.
Path
Default
Range
Units
Writable
Enable Predict Term
0955
Parameters::Motor Control::Current Loop
TRUE
ALWAYS
To enable the predictive term of the current loop.
Functional Description
This is to add the predictive term into the voltage demand formulated by the current regulator so to to increase the dynamic performance of motor
drive. It is recommented to enable this parameter if the permanent magnet motor is used.