Parameter Reference  D-93 
AC30 series Variable Speed Drive 
IO Option Common 
Parameters::Option IO:: Option IO 
 
 
Setup::Inputs and Outputs::Option 
Parameters::Option IO::Option IO 
 
 
0:NONE 
1:GENERAL PURPOSE 
2:THERMISTOR 
3:RTC AND THERMISTOR 
4:PULSE ENCODER 
 
Defines the type of IO option required by the configuration. 
 
Parameters::Option IO::Option IO 
 
Indicates the type of IO option that is currently fitted 
 
Parameters::Option IO::Option IO 
 
 
0:OK 
1:OPTION NOT FITTED 
2:TYPE MISMATCH 
3:TYPE UNKNOWN 
4:HARDWARE FAULT 
 
Indicates the status of the IO option 
Functional Description 
These parameters are used to set and verify the IO Option configuration. If the status parameter is not OK then the drive will not enter the 
Operational state. 
 
The configuration is valid. The status will always be OK if no IO option is required, even if one is fitted. Alternatively, if 
the IO option fitted is working correctly and supports the required functionality then the status will be OK 
For example, if the required type is THERMISTOR and the actual type is GENERAL PURPOSE then the status will 
be OK as the General Purpose option supports the thermistor functionality. 
An option was required and none was detected 
The fitted option does not support the required features 
The firmware in the drive does not recognise the fitted option 
The fitted option is not working as expected.