EasyManua.ls Logo

Parker AC30 - STO State Transition Diagram

Parker AC30
522 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-16 Safe Torque Off
AC30 series Variable Speed Inverter
STO State Transition Diagram
The flow chart below shows how the drive responds to STO inputs, start and stop commands.
Key:
* = One channel operation
** = Two channel operation
Transitional state.
User should avoid
remaining in this
state
Fault state
Normal state
Out-of-box state
Normal startup state
X10/01 low
X10/03 low
Drive cannot run **
X10/01 low
X10/03 high
Drive cannot run *
X10/03 high
X10/01 high
X10/01 low
X10/03 low
X10/01 high
X10/03 low
Drive cannot run *
X10/01 high
X10/03 high
Drive enabled but
not running
X10/03 high
X10/03 low
X10/01 high
X10/01 low
X10/01 high
X10/03 high
Drive runs
X10/03 low
X10/01 low
START command
STOP command
Fault state
Drive cannot run.
ALL Power must
be cycled
2.3 seconds (typical)
2.3 seconds (typical)