Parameter Reference  D-33 
AC30 series Variable Speed Drive 
Configure, (Phase Control) 
Parameters::Phase Control::Configure 
 
Used to select Master and slave encoder source. 
Gives a diagnostics of the configuration related to the encoder selection for the motor control, the Master ( Reference ) and the Slave. 
 
 
Parameters::Phase Control::Configure 
 
 
0:MAIN SPD FEEDBACK 
1:SYSTEM BOARD SLOT 1 
2:SYSTEM BOARD SLOT 2 
3:NONE 
 
Specifies the encoder to be used as the Master, (Reference) input : 
  MAIN SPEED FEEDBACK: corresponds to the I/O feedback option 
  SYSTEM BOARD SLOT 1: corresponds to the Slot 1 of the system board option 
  SYSTEM BOARD SLOT 2: corresponds to the Slot 2 of the system board option 
  NONE : no Master selected 
 
Parameters::Phase Control::Configure 
 
 
0:SAME AS MOTOR FBK 
1:MAIN SPD FEEDBACK 
2:SYSTEM BOARD SLOT 1 
3:SYSTEM BOARD SLOT 2 
 
Specifies the encoder to be used as the Slave input.  Normally this will be the same as the speed feedback. 
  SAME AS MOTOT FBK : the Slave encoder is the encoder used as the motor feedback. 
  MAIN SPEED FEEDBACK : corresponds to the I/O feedback option 
  SYSTEM BOARD SLOT 1 : corresponds to the Slot 1 of the system board option 
  SYSTEM BOARD SLOT 2 : corresponds to the Slot 2 of the system board option 
By default, the value SAME AS MOTOT FBK is selected.  
If the Slave and the Motor Feedback are the same encoder, use SAME AS MOTOT FBK, otherwise, an error 301 or 302 or 303 will 
occur : Motor speed feedback and position feedback ( slave ) cannot be the same. 
 
Parameters::Phase Control::Configure 
 
The configuration of the master, slave and Speed loop encoders is correct