Parameter Reference D-145
AC30 series Variable Speed Drive
Runtime Statistics
Parameters::Device Manager::Runtime Statistics
Parameter Name
No.
Path
Default
Range
Units
Writable
Control Board Up Time
1139
Parameters::Device
Manager::Runtime Statistics
0 to Max
s
NEVER
The total time in seconds for which the control module has been powered, either by 24v or from the 3-phase supply. Set to zero during manufacture.
Time Since Power-On
1733
Parameters::Device
Manager::Runtime Statistics
0.000 to Max
s
NEVER
The time in seconds since power was applied to the control module, either by 24v or from the 3-phase supply.
HV SMPS Up Time
1252
Parameters::Device
Manager::Runtime Statistics
0 to Max
s
NEVER
The time in seconds for which the drive has been powered from the 3-phase supply.
HV Power On Count
1406
Parameters::Device
Manager::Runtime Statistics
0 to 65535
NEVER
The number of times that the drive has been powered up from the 3-phase supply
Motor Run Time
1407
Parameters::Device
Manager::Runtime Statistics
0 to Max
s
NEVER
The time in seconds for which the drive has been controlling a motor
Motor Start Count
1732
Parameters::Device
Manager::Runtime Statistics
0 to Max
NEVER
The total number of motor starts, (from when the control card was manufactured).