Parameter Reference D-43
AC30 series Variable Speed Drive
DC Link Volts Limit
Parameters::Motor Control::Ramp Hold
This function prevents over-voltage faults occurring due to a rapidly changing setpoint.
Parameters::Motor Control::DC Link
Volts Limit
Enable DC Link Volts Limit during a fast deceleration to prevent overvoltage trip
Parameters::Motor Control::DC Link
Volts Limit
Determines the dc link volts at which the DC Link Volts Limit sequence is started.
Entered as a percentage of the max DC link voltage (drive overvoltage level = 100%).
Parameters::Motor Control::DC Link
Volts Limit
Set True when the deceleration ramp is paused in order to limit the DC link voltage
Parameters::Motor Control::DC Link
Volts Limit
This diagnostic represents the speed setpoint output of the Ramp Hold Feature in Electrical Hz