Adjustment
118
Group
Parameter
Description
Setting range
Set value
2
203 Stitch length for starting stitch condensation [0.1 mm] 10 - 30 12
204 Stitch count for starting stitch condensation 1 - 9 5
205 Stitch length for end stitch condensation [0.1 mm] 10 - 30 12
206 Stitch count for end stitch condensation 1 - 9 4
207 Angle seam end [°] 0 - 90 30
208 Stitch count for angle seam end 1 - 9 5
209 Stitch length [0.1 mm] 10 - 30 20
210 Trimming stitch count 1 - 5 2
211 Correction value 1 for starting point
of X-coordinates [0.1 mm]
-100 - 800 0
212 Correction value 2 for starting point
of X-coordinates [0.1 mm]
-100 - 800 0
213 Choice of starting point
0 = starting point 1 (param. 211)
1 = starting point 2 (param. 212)
0 -1
0
214 Correction for last stitch [0.1 mm] -10 - +10 0
3
301 NIS (carriage start) [°] 80 - 150 110
302 Cover thread carrier t.d.c. [°] 80 - 90 82
303 Thread trimming position [°] 160 - 360 200
304 Reverse rotation position [°]
0 - Cover-
thread carrier
t.d.c.
17
305 Thread tension position [°] 0 - 360 200
4
401 Holdoff time between “Table forwards” and “Table ex-
tension off” [0.01 s]
10 - 256 50
402 Holdoff time "Stacker down" [0.01 s] 10 - 256 56
403 Time when tacting the laser [0.01 s] 10 - 256 50
5
501 Maximum speed [min
-1
] 500 - 4300 4300
502 Backtack speed [min
-1
]
500 - max.
speed
max.
speed
503 Trimming speed [min
-1
] 100 - 500 200
504 Speed of the slow starting stitches [min
-1
] 500 - 2000 1000
505 Slow starting stitches 0 - 9 2