Adjustment
13 - 7
13.05.05 Preadjusting the needle height
Requirement
At needle bar position TDC, the distance between the needle point and the adjustment
gauge must be approx. 22 mm.
Move needle bar 1 (screws 2) without twisting it according to the requirement.
Fig. 13 - 06
2
1
22 mm