Adjustment
13 - 44
13.06.11 Position of corner folders
Requirement
1. In folder position, the corner folders 4 must be parallel under the slanted side of the
folder plate and overlap by 1 to 2 mm.
2. The corner folders 4 must be positioned 1 to 2 mm under the folder plates depending
on the fabric thickness.
● Preadjust the clamps 1 (screws 2) according to requirement 1.
● For the final adjustment, turn stop screws 3 according to requirement 1.
● Adjust the corner folders 4 (screws 5) according to requirement 2.
Fig. 13 - 39
4
4
5
1 - 2 mm
1
2
4
5
3
5
4