12 - 4
Care and maintenance
12.04 Cleaning the air filter of the air filter/lubricator unit
The filter element 1 must be
cleaned whenever the working
pressure of 6 bar is no longer
achieved.
Switch off the machine and
ensure that it cannot be
switched on accidentally!
Turn off compressed air!
● Unscrew drum 2.
● Remove filter element 1.
● Clean filer element 1 and drum 2 with
benzine.
● Blast filter element 1 from the inside out
with compressed air.
● Screw on drum 2. (Make sure that the
seals are positioned properly!)
Fig. 12 - 04
1
2
12.05 Checking / regulating air compression
The manometer 1 must
indicate a pressure of 6 bar!
● Always check the air compression on the
manometer 1 before operating the
machine.
● When required, adjust this value by
turning control 2.
When the compressed air is
turned off, the water trap is
emptied automatically. Place a
suitable container underneath
the opening.
Fig. 12 - 05
1