Care and maintenance
12.04 Cleaning the air filter of the air filter/lubricator unit
The filter element 1 must be
cleaned whenever the working
pressure of 6 bar is no longer
achieved.
Switch off the machine and
ensure that it cannot be
switched on accidentally!
Turn off compressed air!
Unscrew drum 2.
Remove filter element 1.
Clean filer element 1 and drum 2 with
benzine.
Blast filter element 1 from the inside out
with compressed air.
Screw on drum 2. (Make sure that the
seals are positioned properly!)
Fig. 12 - 04
1
2
12.05 Checking / regulating air compression
The manometer 1 must
indicate a pressure of 6 bar!
Always check the air compression on the
manometer 1 before operating the
machine.
When required, adjust this value by
turning control 2.
When the compressed air is
turned off, the water trap is
emptied automatically. Place a
suitable container underneath
the opening.
Fig. 12 - 05
1
2