14 - 8
Controller
14.01.05 Stacker motor drive
Before leaving the factory, the stacker motor drive has been set and/or
programmed to meet the requirements of this machine. It may only be
replaced by a programmed drive.
Operation controls
LED H1 (yellow) LED H2 (green) Meaning
off off Power off, no function
on off Power on, after approx. 0.5 s of
self-test ready for operation
off on drive has been started
on on overload protection active
flashes off see
chapter
14.02.04 Errors -
Sewing drive
LED ((green) LED ( red ) Meaning
off off line off - no function
on off machine functional, voltage
outside the set range
on on machine functional, voltage
within the set range
Operation displays
14.01.06 AC-Line-Controller
The AC-Line-Controller is set in the factory to the requirements of this machine.
An exchange is only permissible after prior adjustments.
Default setting
Potentiometer Value
UL (upper limit) 260V
LL (lower limit) 195V
off delay Min.