Adjustment
13 - 16
Fig. 13 - 14
13.05.13 Counter presser position
Requirement
In straight stitch position, when the needle penetrates, it must be centered in the needle
hole of the counter presser 2.
● Pull out plunger 1 until it stops (straight stitch position).
● Adjust the counter presser 2 (screws 3) according to the requirement.
3
3
2
1
2