14 - 1
Controller
14 Controller
14.01 Basic settings/diagnosis/pin assignments
14.01.01 Base control unit A20
In the factory, the base control unit is equipped with the necessary operating
and ramp software. The software may only be replaced by appropriate
specialist personnel.
The setting of the rotary switch is for commissioning and/or trouble shooting of the CAN
bus systems. It has no influence on the machine functions.
Positions of the diagnostic LEDs and switches (see sticker on the device cover).
DO5 DO1 DI5 DI1
DO6 DO2 DI6 DI2
DO7 DO3 DI7 DI3
DO8 DO4 DI8 DI4
Diagnostic-LEDs
CAN-status
BCD switch for setting the
diagnostic function numbers (00-99)
ADR.
*1
ADR.
*10
Diagnostic function 1-8
Indicate highbyte of the inputs of the node 1-8 to be monitored at the diagnostic LEDs
DO8-DO1.
Indicate lowbyte of the inputs of the node 1-8 to be monitored at the diagnostic LEDs
DI8-DI1.
Diagnostic function 11-18
Indicate highbyte of the outputs (set value) of the node 1-8 to be monitored at the diagnostic
LEDs DO8-DO1.
Indicate lowbyte of the outputs (set value) of the node 1-8 to be monitored at the diagnostic
LEDs DI8-DI1.
Diagnostic function 21-28
Indicate highbyte of the outputs (actual value) of the node 1-8 to be monitored at the
diagnostic LEDs DO8-DO1.
Indicate lowbyte of the outputs (actual value) of the node 1-8 to be monitored at the
diagnostic LEDs DI8-DI1.