Controls
7 - 2
7.03 Switch for the loading function
● The function of the switch 1 can be
adapted to the various requirements for
loading the workpiece.
The foot switch is adjusted via
the menu. Refer to chapter
11.05 Functions in the INPUT
mode.
With the needle strip engaged
(needles up) there is danger of
injury near the needle strip due
to the projecting needles!
By selecting the functions BASIC POSITION POCKET PLATE FRONT or BASIC POSITION
POCKET PLATE BACK and by switching the function UNI-MATERIAL on or off, the
following menu combinations can be created:
Menu combinations Switch functions
BASIC POSITION POCKET PLATE FRONT
and UNI-MATERIAL ON
BASIC POSITION POCKET PLATE FRONT on
PLAIN-MATERIAL OFF
1
st
actuation:
Fabric suction/needle strip on.
2
nd
actuation:
Lower pocket plate and raise it a
little.
Switch off fabric suction/needle
strip.
3
rd
and further actuations:
Lower pocket plate and raise it a
little.
Switch fabric suction/needle strip
on/off.
Switch fabric suction/needle strip on/off
Fig. 7 - 03
1