14 - 22
Controller
Ausgang Bezeichnung Index
number
OUT1 ETSTART start label feed 32
OUT2 Y11 no pressure on label retaining clamp or it is 33
open (on edge folder version 4: swivel edge
folders 3)
OUT3 Y12 flap positioning on / variable sewing slot 34
narrow
OUT4 Y13 flap positioning off/ variable sewing slot 35
wide
OUT5 not assigned 36
OUT6 BOBRES reset for bobbin thread monitor 37
OUT7 not assigned 38
OUT8 Y40 hook lubrication on 39
OUT9 STR start stacker motor clockwise 40 ( S )
OUT10 STL start stacker motor anti-clockwise 41 ( S )
OUT11 S1IND stacker motor frequency 1 42 ( S )
OUT12 S2IND stacker motor frequency 2 43 ( S )
OUT13 K53 height adjustment for frame on 44
OUT14 not assigned 45
OUT15 not assigned 46
OUT16 not assigned 47
Node A13/X300