EasyManua.ls Logo

Planmeca Compact i3 - Planmeca Lumion Plus Polymerisation Light Programming; Timer Settings Programming

Planmeca Compact i3
252 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24.4.9 Planmeca Lumion Plus polymerisation light
About this task
NOTE
The duration of the polymerisation cycle can be programmed only for the
Planmeca Lumion Plus polymerisation light.
Steps
1. Activate the instrument.
2. Press Program.
3. Press Polymerisation cycle.
A pop-up window opens.
4. Adjust the length of the polymerisation cycle.
The value range is 5 - 100 seconds. The adjustment step is 5 sec. and
the default value is 10 sec.
5. Press OK.
The pop-up window closes and the new values are displayed on the
control panel.
24.5 Timer settings
About this task
Up to six timer settings can be programmed into the timer memory.
Steps
1. Press Program.
2. Press Timer.
A pop-up window opens.
3. Press the timer that you want to adjust.
A new pop-up window opens.
4. Adjust the length of the timer.
The minimum value is 5 sec. and the maximum 20 min. The adjustment
step is 5 sec.
24 Programming
162 Planmeca Compact i3 User's manual

Table of Contents

Other manuals for Planmeca Compact i3

Related product manuals