The LCD backlight will be inactive automatically if no key has been
pressed for 80 seconds. If the LCD backlight is inactive, the first key
press will activate the backlight, press again to execute the command.
● 1: Always on
The LCD backlight will be always active.
It is recommended to set the LCD backlight mode to "1: Always
on" when [b1.02] = 1 or 2.
b0.08
LCD display in run mode Factory default 0
Setting range 0...17 Minimum unit 1
b0.09
LCD display in stop mode Factory default 2
Setting range 0...17 Minimum unit 1
● 0: Output frequency
● 1: Output rotation speed
● 2: Set frequency
● 3: Set rotation speed
● 4: Output voltage
● 5: Output current
● 6: Output power
● 7: DC bus voltage
● 8: Torque current
● 9: Excitation current
● 10: User-defined reference value
● 11: User-defined output value
● 12: Reference torque
● 13: Digital inputs status
● 14: Encoder speed feedback
● 15: Torque limit setting
● 16: Speed limit setting
● 17: Multi-monitoring display
When [b0.08] or [b0.09] = 13, "Digital inputs status" is displayed as a decimal
value which represents OPEN or CLOSED of 10 digital inputs X1...X8, FWD
and REV. The value of "Digital inputs status" is 0 to 3377.
For example, if "1234" is displayed to indicate the "Digital inputs status", the
respective status of each digital input is shown as the table below.
DOK-RCON02-FV*********-IB08-EN-P Bosch Rexroth AG 103/259
Rexroth Frequency Converter Fv
Parameter Settings