E2.51
Stage 15 action selection Factory default 0
Setting range 0...31 Minimum unit 1
E2.52
Stage 15 running time Factory default 0.0
Setting range 0.0...5,000.0 s Minimum unit 0.1
To set stage 2...stage 15, please refer to the description for stage 1.
If the running time of a stage is set to 0, logic control will skip this stage.
If parameter ‘Motor standard rotation direction’ S3.14 is set to ‘2: Deacti‐
vate reverse motor rotation’, logic control will stop immediately when a
reverse rotation command is executed.
For logic control with external inputs, see parameters E0.01...E0.08.
DOK-RCON02-FV*********-IB08-EN-P Bosch Rexroth AG 149/259
Rexroth Frequency Converter Fv
Parameter Settings