Remote Commands
R&S
®
FSW
977User Manual 1173.9411.02 ─ 19
CALCulate<n>:TLINe<Line> <Time>
This command defines the position of a time line.
Parameters:
<Time> Note that you can not set a time line to a position that is higher
than the current sweep time.
Range: 0 s to 1600 s
*RST: (STATe to OFF)
Example:
CALC:TLIN 10ms
Sets the first time line to 10 ms.
Manual operation: See "Vertical Line 1/2" on page 528
CALCulate<n>:
TLINe<Line>:STATe <State>
This command turns a time line on and off
Parameters:
<State> ON | OFF
*RST: OFF
Example:
CALC:TLIN:STAT ON
Turns the first time line on.
11.8.4.2 Defining Limit Checks
Note that in remote control, upper and lower limit lines are configured using separate
commands. Thus, you must decide in advance which you want to configure. The x-val-
ues for both upper and lower limit lines are defined as a common control line. This con-
trol line is the reference for the y-values for both upper and lower limit lines.
Configuring Limit Lines..........................................................................................977
Managing Limit Lines............................................................................................ 985
Checking the Results of a Limit Check................................................................. 986
Programming Example: Using Limit Lines............................................................ 987
Configuring Limit Lines
CALCulate:LIMit:COMMent.............................................................................................978
CALCulate:LIMit<k>:CONTrol[:DATA].............................................................................. 978
CALCulate:LIMit<k>:CONTrol:DOMain.............................................................................978
CALCulate:LIMit<k>:CONTrol:MODE...............................................................................979
CALCulate:LIMit<k>:CONTrol:OFFSet............................................................................. 979
CALCulate:LIMit<k>:CONTrol:SHIFt................................................................................ 979
CALCulate:LIMit<k>:CONTrol:SPACing............................................................................979
CALCulate:LIMit<k>:LOWer[:DATA].................................................................................980
CALCulate:LIMit<k>:LOWer:MARGin...............................................................................980
CALCulate:LIMit<k>:LOWer:MODE................................................................................. 980
CALCulate:LIMit<k>:LOWer:OFFSet................................................................................980
CALCulate:LIMit<k>:LOWer:SHIFt...................................................................................981
Analyzing Measurements (Basics)

Table of Contents

Other manuals for Rohde & Schwarz FSW26

Related product manuals