Section 3: Operation and Configuration
Page 3-22 HR2 Series Operator Manual
3.7 INTERFACE MODE (Cont’d)
RS-232C CONFIGURATION
Menu Description
Setting RS-232C baud rate.
Press arrow buttons to set the baudrate as 2400, 4800, 9600, 19200, 38400,
57600 or 115200. Press FEED button to save the setting.
The initial value is 19200.
Note: Changed settings will be in effect from the next power on.
Setting RS-232C parity bit.
NONE, ODD or EVEN can be selected.
The initial value is NONE.
Note: Changed settings will be in effect from the next power on.
Setting RS-232C stop bit.
The initial value is 1BIT.
Note: Changed settings will be in effect from the next power on.
Setting RS-232C character bit.
The initial value is 8BIT.
Note: Changed settings will be in effect from the next power on.
Setting communication protocol.
The following protocols are available when RS-232C interface board is
installed.
1) READY/BUSY
2) XON/OFF
3) STATUS2
4) STATUS3
5) STATUS4
6) STATUS5
The initial value is STATUS4.
When READY/BUSY or XON/XOFF is selected, the printer will proceed directly
to RECEIVE BUFFER menu.
When STATUS5 is selected, the printer will proceed directly to ITEM NO
CHECK menu.
When STATUS3 or STATUS4 is selected, the printer will proceed directly to
IGNORE CR/LF menu.
Note: Changed settings will be in effect from the next power on

