Section06ELECTRICALSYSTEM
Subsection 02 (CHARGING SYSTEM)
A17E0FB
2
1
3
1. Sealing tube removed
2. Battery electrolyte
3. Upper level line
– Allow the battery to stand for 30 minutes MIN-
IMUM so that electrolyte soak through battery
cells.
A17E0GA
1
1. 30 minutes
– Readjust the electrolyte level to the UPPER
LEVEL line.
A17E0RB
1
2
1. Battery electrolyte
2. Upper level line
– Connecta2Abatterychargerfor3to5hours.
A17E0IA
-
+
2
1
3
Step 1: Connect + lead to battery + post
Step 2: Connect - lead to battery - post
Step 3: Plug battery charger
WARNING
Gases given off by a battery being charged
are highly explosive. Always charge in a well
ventilated area. Keep battery away from cig-
arettes or open flames. Always turn battery
charger off prior to disconnecting cables.
Otherwise a spark will occur and battery
might explode.
CAUTION: If charging rate raises higher than
2.4 A reduce it immediately. If cell temperature
rises higher than 50°C(122°F) or if the casing
feels hot, discontinue charging temporarily or
reduce the charging rate.
– Disconnect battery charger.
160 smr2005-016