CDHD Drive Setup
User Manual 103
Ta ble 5 - 3 7 . Mot or I nterface Mating Connect ors
I te m CD HD- 1 D5 , CD HD - 0 0 3
Manufacturer JST J300
Housing and
4-pin crimp
F32FSS-04V-KX and
SF3F-71GF-P2.0
Spring term inal 04JFAT-SBXGF-I (supplied)
Wire gauge 18 AWG
I te m CD HD- 4 D5 , CD HD - 0 0 6
Manufacturer JST J300
Housing and
4-pin crimp
F32FSS-04V-KX and
SF3F-71GF-P2.0
Spring t erm inal 04JFAT-SBXGF-I (supplied)
Wire gauge 16 AWG
I te m CD HD- 0 0 8 , CDHD - 0 1 0 , CD HD -0 1 3
Manufacturer JST J400
Housing and
4-pin crimp
J43FSS-04V-KX (supplied) and
SJ4F-71GF-M3.0 (supplied)
Spring term inal Not available
Wire gauge 14 AWG
I te m CD HD- 0 2 0 , CDHD - 0 2 4
Manufacturer Phoenix Contact
Spring term inal
SPC 5/ 4-STCL-7,62 (1718504) (supplied)
Wire gauge 10-11 AWG
5 .7 .3 Rege nerat ion Resist or
Regen uses interface P3 on all CDHD 120/ 240 VAC m odels.
Exception: Re gen uses P5 on CDHD-020/ 024.
N ote: On m odels CDHD-1D5 and CDHD-003, Regen and AC I nput Voltage
are com bined on one connector.
If the application requires a regeneration (regen) resistor, connect the regen
resistor between terminals B1+ and B2.