Diagnostics and Troubleshooting CDHD
238 User Manual
- 1 N ot Configure d
-1 Displayed in sequence
D e finit ion Not Configured
Type Fault
Act ive disa ble Not applicable
M e ssage # FLT 12
Descr iption Drive configuration required.
CONFI G is required aft er the value of any of cert ain
param eters is m odified.
CONFI G is also required after certain parameters are sent
to the drive, even if their value has not been changed.
Action required Set drive paramet ers and/ or and execute CONFIG.
_ Rea lt im e Ove rloa d W ar ning
_ Lit steadily
D e finit ion Realtime Overload Warning
Type Warning
Act ive disa ble Not Applicable
M e ssage # WRN 36
Descr iption
Drive has detected that CPU is close to its computational
lim it.
Action required
_ Rea lt im e Ove rloa d Fault
_ Flashing
D e finit ion Realtime Overload Fault
Type Fault
Act ive disa ble No
M e ssage # FLT 89
Descr iption
CPU has exceeded its computational limit. Realtime
execution takes longer than 31.25 µs.
This fault disables the drive.
Action required Contact Technical Support