EasyManua.ls Logo

Servotronix CDHD Series - Page 241

Servotronix CDHD Series
292 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CDHD Diagnostics and Troubleshooting
User Manual 241
8 Profile Position Mode
8 Lit steadily
D e finit ion Profile Position Mode
8 = drive disabled; 8. = drive enabled
Type Mode
Act ive disa ble Not applicable
M e ssage # Not applicable
Descr iption Not applicable
Action required Not applicable
8 . H a rdw are Em ber Sw it ch Activat e d
8. All segments of the LED display light up mom entarily
D e finit ion Hardware Em ber Switch Activated
Type Not applicable
Act ive disa ble Not applicable
M e ssage # Not applicable
Descr iption
All segm ents of the LED display light up when the
Hardware Ember switch is activated. Pressing the switch
sets the drive to serial communication Boot-Up Mode.
Action required Not applicable
A4 CAN Supply Fa ult
A4 Displayed in sequence
D e finit ion CAN Supply Fault
Type Fault
Act ive disa ble Yes
M e ssage # FLT 32
Descr iption
A problem with the internal voltage supply for the CAN
bus.
This fault disables the drive.
Action required
The drive probably needs repair. Cont act Technical
Support.

Table of Contents