CDHD Diagnostics and Troubleshooting
User Manual 265
o1 5 Plus 1 5 V Out of Range
o15 Displayed in sequence
D e finit ion Plus 15V Out of Range
Type Fault
Act ive disa ble Yes
M e ssage # FLT 36
Descr iption The internal + 15 V supply is out of range.
This fault disables the drive.
Action required
The drive probably needs repair. Cont act Technical
Support.
o- 1 5 M inu s 1 5 V Ou t of Ra nge
o-15 Displayed in sequence
D e finit ion Minus 15V Out of Range
Type Fault
Act ive disa ble Yes
M e ssage # FLT 37
Descr iption The internal -15 V supply is out of range.
This fault disables the drive.
Action required
The drive probably needs repair. Cont act Technical
Support.
o5 5 V Ou t of Ra n ge
o5 Displayed in sequence
D e finit ion 5V Out of Range
Type Fault
Act ive disa ble Yes
M e ssage # FLT 52
Descr iption 5V is low or powering off.
This fault disables the drive.
Action required
May occur during power off. I f it occurs under other
condit ions, contact Technical Support .

Table of Contents