CDHD Diagnostics and Troubleshooting
User Manual 273
r2 0 Fee dba ck Com m unica tion Error
r20 Displayed in sequence
D e finit ion Feedback Com munication Error
Type Fault
Act ive disa ble No
M e ssage # FLT 34
Descr iption
Com m unication with the feedback device did not init ialize
correctly.
This fault disables the drive.
Action required
Check that the feedback device is wired correctly. Check
that the correct encoder type (MENCTYPE) is selected.
r2 1 Nikon Encode r Opera t iona l Fault
r21 Displayed in sequence
D e finit ion Nikon Encoder Operational Fault
Type Fault
Act ive disa ble No
M e ssage # FLT 35
Descr iption
Com m unication with the Nikon feedback device did not
initialize correctly.
This fault disables the drive.
Action required
Check that the feedback device is wired correctly. Check
that the correct encoder type (MENCTYPE) is selected.