Chapter 11 Operating instructions
S3000
136 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8009942/WK81/2012-11-28
Subject to change without notice
Diagnostics
Display Possible cause Rectification of the error
Object in the first
protective field of the
simultaneous field set
or
Surrounding contour
27)
changed
No error
Object in the second
protective field of the
simultaneous field set
or
Surrounding contour
2
7)
changed
No error
Indication of protective field and warning field infringements in the triple field mode
Object in
protective field
No error
Object in
warning field 1
No error
Object in
warning field 2
No error
Show for all field modes
Initialization of the
device
Or
Waiting for the end of
the initialization of a
second device
connected to the EFI
The display goes out automatically when the
S3000 has been initialized and/or the
connection to the second device has been
made.
If the display does not go off:
Check whether the partner device is in
operation.
Check the wiring.
If no partner device is connected:
Check the system configuration with the aid
of the CDS. Transfer the corrected
configuration to the S3000 again.

Table of Contents