EasyManuals Logo

Siemens FUS1010 User Manual

Siemens FUS1010
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
Connecting
5.5 Sensor Installation
FUS1010 IP65 NEMA 4X & IP66 NEMA 7
62 Operating Instructions, 01/2013, A5E02951520-AC
Preparing the Pipe
1. On a flat surface, attach the Spacer Bar to a Mounting Frame so that the Reference Hole
on the Spacer Bar fits over the metal post on the platform of the frame. Tighten the
clamping screw.
2. Slide the second Mounting Frame onto the other end of the Spacer Bar and align the
Number Index Hole with the metal post on the platform. Then tighten the clamping screw.
Ensure that the angled sides of both frames face away from each other.
3. Wrap a Mounting Strap around the pipe. Make sure to position it so there is easy access
to the Mounting Strap Adjusting Screw.
4. At the mounting location, place the Mounting Frame/Spacer Bar Assembly on the pipe so
that it rests on the top of the pipe.
5. Engage the end of the Mounting Strap with the Mounting Strap Adjusting Screw.
6. Slide strap under the spring clip of one of the Mounting Frames.
7. Tighten the Mounting Strap Screw enough to take up all of the slack, but not enough to
prevent rotation of the assembly.
Repeat procedure for the other Mounting Frame
.
8. Rotate the assembly on the pipe to the final conditioned location, ensuring that it is
straight along the pipe axis. (Refer to the sensor orientation diagram)
9. Tighten the mounting straps to seat the assembly firmly on the pipe. Do not over tighten.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens FUS1010 and is the answer not in the manual?

Siemens FUS1010 Specifications

General IconGeneral
BrandSiemens
ModelFUS1010
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals