EasyManua.ls Logo

Siemens RUGGEDCOM ROS - Managing RMON Events

Siemens RUGGEDCOM ROS
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3
Device Management
RUGGEDCOM ROS
User Guide
94 Managing RMON Events
14
12
13
1
2
3
4
5
6
7
8
9
10
11
Figure 57: RMON Alarms Form
1. Index Box 2. Variable Box 3. Rising Thr Box 4. Falling Thr Box 5. Value Box 6. Type Options 7. Interval Box 8. Startup
Alarm List 9. Rising Event Box 10. Falling Event Box 11. Owner Box 12. Apply Button 13. Delete Button 14. Reload Button
3. Click Delete.
Section 3.10.3
Managing RMON Events
Remote Monitoring (RMON) events define behavior profiles used in event logging. These profiles are used by
RMON alarms to send traps and log events.
Each alarm may specify that a log entry be created on its behalf whenever the event occurs. Each entry may
also specify that a notification should occur by way of SNMP trap messages. In this case, the user for the trap
message is specified as the Community.
Two traps are defined: risingAlarm and fallingAlarm.
The following sections describe how to configure and manage RMON events:
Section 3.10.3.1, “Viewing a List of RMON Events”
Section 3.10.3.2, “Adding an RMON Event”
Section 3.10.3.3, “Deleting an RMON Event”

Table of Contents

Related product manuals