Chapter 3
Device Management
RUGGEDCOM ROS
User Guide
46 Restoring Factory Defaults
Parameter Description
The size of RAM that have never been used during the system runtime.
Temperature Synopsis: -32768 to 32767 C
The temperature on CPU board.
Free Rx Bufs Synopsis: 0 to 4294967295
Free Rx Buffers.
Free Tx Bufs Synopsis: 0 to 4294967295
Free Tx Buffers.
Section 3.3
Restoring Factory Defaults
The device can be completely or partially restored to its original factory default settings. Excluding groups of
parameters from the factory reset, such as those that affect basic connectivity and SNMP management, is useful
when communication with the device is still required during the reset.
The following categories are not affected by a selective configuration reset:
• IP Interfaces
• IP Gateways
• SNMP Users
• SNMP Security to Group Maps
• SNMP Access
• RUGGEDCOM Discovery Protocol™ (RCDP)
In addition, the following categories are not affected by a full or selective configuration reset:
• Time Zone
• DST Offset
• DST Rule
To restore factory defaults, do the following:
1. Navigate to Diagnostics » Load Factory Defaults. The Load Factory Defaults form appears.
3
2
1
Figure 10: Load Factory Defaults Form
1. Defaults Choice List 2. Apply Button 3. Reload
2. Configure the following parameter(s) as required:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROS and is the answer not in the manual?

Siemens RUGGEDCOM ROS Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROS
CategoryControl Unit
LanguageEnglish

Related product manuals