Chapter 5
Setup and Configuration
RUGGEDCOM ROS
User Guide
186 Deleting an SNMP User
Parameter Description
user, but from any other IP address.If IP address is empty, traps can not be generated to
this user, but SNMP requests will be served for this user from any IP address.
v1/v2c Community Synopsis: Any 32 characters
The community string which is mapped by this user/security name to the security group
if security model is SNMPv1 or SNMPv2c. If this string is left empty, it will be assumed to
be equal to the same as user name.
Auth Protocol Synopsis: { noAuth, HMACMD5 }
Default: noAuth
An indication of whether messages sent on behalf of this user to/from SNMP engine,
can be authenticated, and if so, the type of authentication protocol which is used.
Priv Protocol Synopsis: { noPriv, CBC-DES }
Default: noPriv
An Indication of whether messages sent on behalf of this user to/from SNMP engine can
be protected from disclosure, and if so, the type of privacy protocol which is used.
Auth Key Synopsis: 31 character ASCII string
The secret authentication key (password) that must be shared with SNMP client. If the
key is not an emtpy string, it must be at least 6 characters long.
Confirm Auth Key Synopsis: 31 character ASCII string
The secret authentication key (password) that must be shared with SNMP client. If the
key is not an emtpy string, it must be at least 6 characters long.
Priv Key Synopsis: 31 character ASCII string
The secret encription key (password) that must be shared with SNMP client. If the key is
not an emtpy string, it must be at least 6 characters long.
Confirm Priv Key Synopsis: 31 character ASCII string
The secret encription key (password) that must be shared with SNMP client. If the key is
not an emtpy string, it must be at least 6 characters long.
4. Click Apply.
Section 5.7.1.3
Deleting an SNMP User
To delete an SNMP user, do the following:
1. Navigate to Administration » Configure SNMP » Configure SNMP Users. The SNMP Users table
appears.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROS and is the answer not in the manual?

Siemens RUGGEDCOM ROS Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROS
CategoryControl Unit
LanguageEnglish

Related product manuals