RUGGEDCOM ROS
User Guide
Chapter 3
Device Management
Configuring the Remote Syslog Client 53
Section 3.5.4.3, “Adding a Remote Syslog Server”
Section 3.5.4.4, “Deleting a Remote Syslog Server”
Section 3.5.4.1
Configuring the Remote Syslog Client
To configure the remote syslog client, do the following:
1. Navigate to Administration » Configure Syslog » Configure Remote Syslog Client. The Remote Syslog
Client form appears.
32
1
Figure 14: Remote Syslog Client Form
1. UDP Port 2. Apply Button 3. Reload Button
2. Configure the following parameter(s) as required:
Parameter Description
UDP Port Synopsis: 1025 to 65535 or { 514 }
Default: 514
The local UDP port through which the client sends information to the server(s).
3. Click Apply.
Section 3.5.4.2
Viewing a List of Remote Syslog Servers
To view a list of known remote syslog servers, navigate to Administration » Configure Syslog » Configure
Remote Syslog Server. The Remote Syslog Server table appears.

Table of Contents