Power Modules
4.3 Power Modules Blocksize (PM340)
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
157
Figure 4-54 Output current as a function of the installation altitude
It is not permissible that the Power Module is operated with its maximum rated current at
output frequencies below 10 Hz. Otherwise, its service life could be reduced.
Figure 4-55 Output current as a function of the output frequency