Power Modules
4.2 Blocksize Power Modules (PM240-2)
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
111
Table 4- 11 Technical data of the PM240-2, FSA (400 V) (1/2)
Line voltage 3-phase 380 … 480 VAC ± 10%
Order number
without integrated line filter
with integrated line filter
6SL3210–
1PE11-8UL1
1PE11-8AL1
6SL3210–
1PE12-3UL1
1PE12-3AL1
6SL3210–
1PE13-2UL1
1PE13-2AL1
6SL3210–
1PE14-3UL1
1PE14-3AL1
Rated current I
n
Base-load current I
H
for S6 operation (40%) l
s6
max
A
A
A
1,7
1,3
2,0
2,2
1,7
2,5
3,1
2,2
3,5
4,1
3,1
4,5
1)
based on I
n
kW
kW
0,55
0,37
0,75
0,55
1,1
0,75
1,5
1,1
3
2)
with/without integrated line reactor
A 2,3 2,9 4,1 5,5
Rated current
Short-circuit current rating
A
4
4
6
10
3NA3 804
3NA3 804
3NA3 801
3NA3 803
of the external
Ω ≥ 370 ≥ 370 ≥ 370 ≥ 370
Max. cable length
to braking resistor
L1, L2, L3,
Screw-type terminals
cable cross-section: 1.5 … 2.5 mm
2
Tightening torque: 0.5 Nm
Motor connection U2, V2, W2
DC-link connection, connection for
braking resistor
DCP/R1, DCN, R2