Table 7- 44 X224 electronics power supply
Terminal
Function
Technical data
+
Electronics power supply
Voltage: 24 VDC (20.4 ... 28.8 VDC)
Current consumption: max. 0.8 A (without DRIVE-CLiQ)
Max. current via jumper in connector: 20 A (15 A
according to UL/CSA)
+
Electronics power supply
GND
Electronics ground
GND Electronics ground
Type: Screw-type terminal 2 (Page 437)
Max. cross-section that can be connected: 2.5 mm
2
The maximum cable length that can be connected is 10 m.
Note
The two "+" and/or "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
The current consumption increases by the value for the DRIVE
-CLiQ node.