Supplementary system components and encoder system integration
8.1 Sensor Modules
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
369
Meaning of the LEDs
Meaning of LEDs on the Sensor Module Cabinet-Mounted SMC30
Table 8- 16 Meaning of LEDs on the Sensor Module Cabinet SMC30
RDY
READY
– Off The electronics power supply is missing or outside the
permissible tolerance range.
–
Green Continuou
The component is ready for operation. Cyclic DRIVE-CLiQ
communication is taking place.
–
Orange Continuou
DRIVE-CLiQ communication is being established. –
Red Continuou
s light
This component has at least one fault.
LED is controlled irrespective of the corresponding
messages being reconfigured.
Remedy and
acknowledge fault
Green/red Flashing
light 0.5
Firmware is being downloaded. –
Green/red Flashing
Firmware download is complete. The system waits for
Carry out a POWER
Green/ora
nge
or
Red/orang
e
Flashing
light
Component recognition via LED is activated
1)
.
Both options depend on the LED status when component
recognition is activated.
–
OUT > 5
V
– Off The electronic power supply is missing or outside
permissible tolerance range.
–
Orange Continuou
s light
The electronics power supply for the encoder system is
available.
Power supply > 5 V
Make sure that the connected encoder can be operated with
a 24
V power supply. If an encoder that is designed for a 5 V
supply is operated with a 24 V supply, this can destroy the
–
1)
See SINAMICS S120/S150 List Manual for the parameters to activate the recognition of components via LED
Cause and rectification of faults
The following documents contain information about the cause of faults and how they can be
rectified:
SINAMICS S120 Commissioning Manual (IH1)
SINAMICS S120/S150 List Manual (LH1)